150V RK8318-150-12/RK8336-150-24/RK8360-150-40/RK8375-150-50/RK83120-150-80/RK83150-150-100 Programmable DC stabilized power supply
Product Introduction
The DC stabilized voltage and current power supply is a high-performance power supply independently developed and produced by our company for scientific research and industrial applications. By adopting high-frequency switching power supply technology, heat generation is significantly reduced, while machine losses are minimized, power efficiency is improved, and machine lifespan is extended.
The transformer is made of purple copper wire material to reduce heat loss. The radiator adopts a customized high-density tooth radiator to improve heat dissipation efficiency. The fan adopts a speed regulating fan, which automatically adjusts the speed according to the output power, reduces fan noise, and extends the service life of the fan,
All other components are made of high-quality domestic and foreign components, which greatly improves the overall performance of the power supply.
This series of products features simple operation, small size, high efficiency, high precision, and high stability. Equipped with a high brightness digital tube, it has complete protection functions such as overvoltage, overcurrent, overtemperature, and short circuit, making users feel more confident, stable, and reliable when using the product.
It is a preferred choice for research institutions, laboratory testing, production line product testing, and industrial application power supply.
application area
Widely used in industries such as home appliance manufacturing, motor and electronics manufacturing, IT industry, and computer equipment manufacturing, as well as laboratories and electronic and electrical product testing institutions.
Performance characteristics
1. Output voltage 0-2000V rated voltage, output current 0-500A rated current, maximum single machine 15KW;
2. The panel comes with preset buttons that allow for pre-set voltage and current values;
3. The voltage and current values can be continuously adjusted from zero to the rated value, and the automatic conversion of voltage and current regulation is achieved;
4. The overvoltage protection value can be set, and the output will automatically shut down when the output voltage reaches or exceeds the overvoltage protection value;
5. Equipped with memory function, it can save preset voltage, current, overvoltage protection values, etc. when turned off;
6. External voltage sampling line to reduce voltage errors caused by long output wires and achieve flexible switching of voltage sampling signals (optional);
7. The power output signal can be controlled by analog quantities ranging from 0~5V, 0~10V, or 4~20mA, and the power output signal can be read (optional)
| voltage | model | current | power | current resolution | Voltage resolution | Input voltage (V) | Dimensions (width * depth * height mm) | Weight (Kg) | |
|
30V |
RK8309-30-30 |
30A |
900W |
1mA |
1mV |
AC220V±10%,50Hz |
215×360×88 |
2U? |
5.5 |
|
RK8318-30-60 |
60A |
1.8KW |
1mA |
1mV |
AC220V±10%,50Hz |
215×360×88 |
2U? |
7.5 |
|
|
RK8336-30-120 |
120A |
3.6KW |
10mA |
1mV |
AC220V±10%,50Hz |
215×400×88 |
2U? |
7.5 |
|
|
430×420×88 |
2U |
10.5 |
|||||||
|
RK8360-30-200 |
200A |
6KW |
10mA |
1mV |
AC220V±10%,50Hz |
430×500×88 |
2U |
16 |
|
|
AC380V±10%,50Hz |
|||||||||
|
RK8375-30-250 |
250A |
7.5KW |
10mA |
1mV |
AC380V±10%,50Hz |
430×500×88 |
2U |
16 |
|
|
RK83120-30-400 |
400A |
12KW |
10mA |
1mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
RK83150-30-500 |
500A |
15KW |
10mA |
1mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
60V |
RK8309-60-15 |
15A |
900W |
1mA |
1mV |
AC220V±10%,50Hz |
215×360×88 |
2U? |
5.5 |
|
RK8318-60-30 |
30A |
1.8KW |
1mA |
1mV |
AC220V±10%,50Hz |
215×360×88 |
2U? |
5.5 |
|
|
RK8336-60-60 |
60A |
3.6KW |
1mA |
1mV |
AC220V±10%,50Hz |
215×400×88 |
2U? |
7.5 |
|
|
430×420×88 |
2U |
10.5 |
|||||||
|
RK8360-60-100 |
100A |
6KW |
10mA |
1mV |
AC220V±10%,50Hz |
430×500×88 |
2U |
16 |
|
|
AC380V±10%,50Hz |
|||||||||
|
RK8375-60-125 |
125A |
7.5KW |
10mA |
1mV |
AC380V±10%,50Hz |
430×500×88 |
2U |
16 |
|
|
RK83120-60-200 |
200A |
12KW |
10mA |
1mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
RK83150-60-250 |
250A |
15KW |
10mA |
1mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
100V |
RK8310-100-10 |
10A |
900W |
1mA |
10mV |
AC220V±10%,50Hz |
215×360×88 |
2U? |
5.5 |
|
RK8318-100-18 |
18A |
1.8KW |
1mA |
10mV |
AC220V±10%,50Hz |
215×360×88 |
2U? |
5.5 |
|
|
RK8336-100-36 |
36A |
3.6KW |
1mA |
10mV |
AC220V±10%,50Hz |
215×400×88 |
2U? |
7.5 |
|
|
430×420×88 |
2U |
10.5 |
|||||||
|
RK8360-100-60 |
60A |
6KW |
1mA |
10mV |
AC220V±10%,50Hz |
430×500×88 |
2U |
16 |
|
|
AC380V±10%,50Hz |
|||||||||
|
RK8375-100-75 |
75A |
7.5KW |
1mA |
10mV |
AC380V±10%,50Hz |
430×500×88 |
2U |
16 |
|
|
RK83100-100-100 |
100A |
10KW |
10mA |
10mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
RK83150-100-150 |
150A |
15KW |
10mA |
10mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
150V |
RK8318-150-12 |
12A |
1.8KW |
1mA |
10mV |
AC220V±10%,50Hz |
215×360×88 |
2U? |
5.5 |
|
RK8336-150-24 |
24A |
3.6KW |
1mA |
10mV |
AC220V±10%,50Hz |
215×400×88 |
2U? |
7.5 |
|
|
430×420×88 |
2U |
10.5 |
|||||||
|
RK8360-150-40 |
40A |
6KW |
1mA |
10mV |
AC220V±10%,50Hz |
430×500×88 |
2U |
16 |
|
|
AC380V±10%,50Hz |
|||||||||
|
RK8375-150-50 |
50A |
7.5KW |
1mA |
10mV |
AC380V±10%,50Hz |
430×500×88 |
2U |
16 |
|
|
RK83120-150-80 |
80A |
12KW |
1mA |
10mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
RK83150-150-100 |
100A |
15KW |
10mA |
10mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
200V |
RK8318-200-9 |
9A |
1.8KW |
1mA |
10mV |
AC220V±10%,50Hz |
215×360×88 |
2U? |
5.5 |
|
RK8336-200-18 |
18A |
3.6KW |
1mA |
10mV |
AC220V±10%,50Hz |
215×400×88 |
2U? |
7.5 |
|
|
430×420×88 |
2U |
10.5 |
|||||||
|
RK8360-200-30 |
30A |
6KW |
1mA |
10mV |
AC220V±10%,50Hz |
430×500×88 |
2U |
16 |
|
|
AC380V±10%,50Hz |
|||||||||
|
RK8372-200-36 |
36A |
7.2KW |
1mA |
10mV |
AC380V±10%,50Hz |
430×500×88 |
2U |
16 |
|
|
RK83100-200-50 |
50A |
10KW |
1mA |
10mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
RK83150-200-75 |
75A |
15KW |
1mA |
10mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
300V |
RK8318-300-6 |
6A |
1.8KW |
1mA |
10mV |
AC220V±10%,50Hz |
215×360×88 |
2U? |
5.5 |
|
RK8336-300-12 |
12A |
3.6KW |
1mA |
10mV |
AC220V±10%,50Hz |
215×400×88 |
2U? |
7.5 |
|
|
430×420×88 |
2U |
10.5 |
|||||||
|
RK8360-300-20 |
20A |
6KW |
1mA |
10mV |
AC220V±10%,50Hz |
430×500×88 |
2U |
16 |
|
|
AC380V±10%,50Hz |
|||||||||
|
RK8375-300-25 |
25A |
7.5KW |
1mA |
10mV |
AC380V±10%,50Hz |
430×500×88 |
2U |
16 |
|
|
RK83120-300-40 |
40A |
12KW |
1mA |
10mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
RK83150-300-50 |
50A |
15KW |
1mA |
10mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
600V |
RK8318-600-3 |
3A |
1.8KW |
1mA |
10mV |
AC220V±10%,50Hz |
215×400×88 |
2U? |
7.5 |
|
RK8336-600-6 |
6A |
3.6KW |
1mA |
10mV |
AC220V±10%,50Hz |
215×400×88 |
2U? |
7.5 |
|
|
430×420×88 |
2U |
10.5 |
|||||||
|
RK8360-600-10 |
10A |
6KW |
1mA |
10mV |
AC220V±10%,50Hz |
430×500×88 |
2U |
16 |
|
|
AC380V±10%,50Hz |
|||||||||
|
RK8372-600-12 |
12A |
7.2KW |
1mA |
10mV |
AC380V±10%,50Hz |
430×500×88 |
2U |
16 |
|
|
RK83120-600-20 |
20A |
12KW |
1mA |
10mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
RK83150-600-25 |
25A |
15KW |
1mA |
10mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
1000V |
RK8330-1000-3 |
3A |
3KW |
1mA |
100mV |
AC220V±10%,50Hz |
430×500×88 |
2U |
16 |
|
RK8350-1000-5 |
5A |
5KW |
1mA |
100mV |
AC220V±10%,50Hz |
430×500×88 |
2U |
16 |
|
|
RK83100-1000-10 |
10A |
10KW |
1mA |
100mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
RK83150-1000-15 |
15A |
15KW |
1mA |
100mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
1200V |
RK8336-1200-3 |
3A |
3.6KW |
1mA |
100mV |
AC220V±10%,50Hz |
430×500×88 |
2U |
16 |
|
RK8360-1200-5 |
5A |
6KW |
1mA |
100mV |
AC220V±10%,50Hz |
430×500×88 |
2U |
16 |
|
|
AC380V±10%,50Hz |
|||||||||
|
1500V |
RK8315-1500-1 |
1A |
1.5KW |
1mA |
100mV |
AC220V±10%,50Hz |
430×500×88 |
2U |
10.5 |
|
RK8375-1500-5 |
5A |
7.5KW |
1mA |
100mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
RK83150-1500-10 |
10A |
15KW |
1mA |
100mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
26 |
|
|
2000V |
RK8320-2000-1 |
1A |
2KW |
1mA |
100mV |
AC220V±10%,50Hz |
430×500×88 |
2U |
10.5 |
|
RK8320-2000-2 |
2A |
2KW |
1mA |
100mV |
AC220V±10%,50Hz |
430×500×88 |
2U |
16 |
|
|
RK83100-2000-5 |
5A |
10KW |
1mA |
100mV |
AC380V±10%,50Hz |
430×560×132 |
3U |
2 |
|
| project | parameter | |||||
| AC input | Single-phase | AC220V±10%, 50Hz, power ≤6KW | ||||
| Three-phase | AC380V±10%, 50Hz, power ≥6KW | |||||
| DC output | Output voltage | 0V – Rated value Refer to the selection specification table | ||||
| Output current | 0A – Rated value Refer to the selection specification table | |||||
| Load regulation | Voltage | ≤0.3%F.S+10mV | ||||
| Current | ≤0.3%F.S+10mA | |||||
| Set value accuracy | Voltage | ≤0.3%+20mV | ||||
| Current | ≤0.3%+20mA | |||||
| Readback value accuracy | Voltage | ≤0.3%+20mV | ||||
| Current | ≤0.3%+20mA | |||||
| Ripple (20Hz-20MHz) | Voltage | Vrms≤0.3%F.S+50mV | ||||
| Dynamic response time (10%-90% load) | ≤5mS | |||||
| Display mode | 5-digit digital meter (LED digital tube display) | |||||
| Display resolution | Voltage 1mV/10mV/100mV, current 1mA/10mA (different specifications of power supply display different) | |||||
| Communication interface | RS232/RS485 digital interface; 0-5V/0-10V, 4-20mA analog interface | |||||
| Function protection | Overvoltage protection, overcurrent protection, overtemperature protection, short circuit protection | |||||
| Heat dissipation method | Adopt PWM speed control fan, air cooling | |||||
| Operating environment | Designed for indoor use, temperature 0℃ – 40℃; humidity 10% -85%RH | |||||
| Storage environment | Designed for indoor storage, temperature -20℃ – 70℃; humidity 10% -90%RH | |||||
| Special requirements | Please specify in advance before ordering | |||||
|
Models within 8KW |
|||
|
model |
picture |
type |
summary |
|
Voltage compensation short plug |
|
standard configuration |
The instrument comes standard with voltage compensation short plug, which can be purchased separately. |
|
RK00001 power cord |
|
standard configuration |
The instrument comes standard with national standard power cord, which can be purchased separately. |
|
DB9 plug |
? |
standard configuration |
The instrument comes standard with DB9 plug, which can be purchased separately. |
|
4P plug -RS485 |
? |
standard configuration |
The instrument comes standard with 4P plug -RS485, which can be purchased separately. |
|
Instructions |
? |
standard configuration |
The instrument comes standard with the product instruction manual. |
|
Certificate warranty card |
? |
standard configuration |
The instrument comes standard with a warranty card. |
|
Models within 6KW |
|||
|
model |
picture |
type |
summary |
|
Voltage compensation short plug |
|
standard configuration |
The instrument comes standard with voltage compensation short plug, which can be purchased separately. |
|
DB9 plug |
? |
standard configuration |
The instrument comes standard with DB9 plug, which can be purchased separately. |
| 3P input terminal |
? |
standard configuration |
The instrument comes standard with 3P input terminal, which can be purchased separately. |
|
Instructions |
? |
standard configuration |
The instrument comes standard with the product instruction manual. |
|
Certificate warranty card |
? |
standard configuration |
The instrument comes standard with a warranty card. |
| Models above 6KW-15kw | |||
|
model |
picture |
type |
summary |
|
Voltage compensation short plug |
|
standard configuration |
The instrument comes standard with voltage compensation short plug, which can be purchased separately. |
|
DB9 plug |
? |
standard configuration |
The instrument comes standard with DB9 plug, which can be purchased separately. |
|
4P plug -RS485 |
? |
standard configuration |
The instrument comes standard with 4P plug -RS485, which can be purchased separately. |
|
Instructions |
? |
standard configuration |
The instrument comes standard with the product instruction manual. |
|
Certificate warranty card |
? |
standard configuration |
The instrument comes standard with a warranty card. |